| Model |
SRAID116-U320 |
SRAID116 |
SRAID114 |
| Online Documentation |
Hardcopy only - online version coming
soon |
Hardcopy only - online version coming
soon |
Available |
| Form-factor |
3U 19 inch rackmount
(EIA RS-310C compliant) |
3U 19 inch rackmount
(EIA RS-310C compliant) |
3U 19 inch rackmount
(EIA RS-310C compliant) |
| RAID
processor |
Intel 80321 64 bit RISC |
Intel 80303 64 bit RISC |
Intel 80303 64 bit RISC |
| RAID
level |
0, 1 , 0+1, 3, 5, 30, 50, JBOD |
0, 1, 0+1, 3, 5 |
0, 1, 0+1, 3, 5, JBOD |
| Cache
memory |
128 MB to 1024 MB |
128 MB to 512 MB |
128 MB to 512 MB |
| No. of
channels (host + drive) |
2 + 16 |
2 + 16 |
2 + 14 |
| Host
bus interface (standard) |
Ultra 320 LVD |
Ultra 160 LVD |
Ultra 160 LVD |
| Data
transfer rate (standard) |
Up to 320 MB / Sec |
Up to 160 MB / Sec |
Up to 160 MB / Sec |
| Host
bus interface (fiber) |
FC-AL x 2 (2 GB / Sec) |
FC-AL x 2 (2 GB / Sec) |
FC-AL x 2 (2 GB / Sec) |
| Data
transfer rate (fiber) |
Up to 200 MB / Sec |
Up to 200 MB / Sec |
Up to 200 MB / Sec |
| Drive
bus interface |
S-ATA 150 |
S-ATA 150 |
UDMA133 |
| Back
plane board |
S-ATA 150 |
S-ATA 150 |
UDMA133 (SCA-II) |
| Drive
tray |
Sixteen hot-swappabe 1-inch trays |
Sixteen hot-swappabe 1-inch trays |
Fourteen hot-swappable
1-inch trays w/ SCA-II 80 pin connectors |
| Power
supply |
Three 300 Watt hot-swap
redundant w/ PFC correction |
Three 300 Watt hot-swap
redundant w/ PFC correction |
Three 300 Watt hot-swap
redundant w/1 PFC correction |
| Tagged
command queuing |
Up to 256 commands |
Up to 255 commands |
Up to 255 commands |
| Cooling
units |
Two hot-swappable blowers |
Two hot-swappable blowers |
Two hot-swappable blowers |
| Fax/Pager
notification |
Yes - serial port + ethernet port |
Yes - serial port + ethernet port |
Yes - serial port |
| Browser-based
Java GUI management utility |
Yes |
Yes |
Yes |
| Password
protection |
Yes |
Yes |
Yes |
| Audible
alarm |
Yes |
Yes |
Yes |
| Failed
drive indicators |
Yes |
Yes |
Yes |
| Failed
drive auto rebuild |
Yes |
Yes |
Yes |
| On-line
consistency check |
Yes |
Yes |
Yes |
| Continuous
rebuild |
Yes |
Yes |
Yes |
| On-line
expansion |
Yes |
Yes |
Yes |
| Host
independent |
Yes |
Yes |
Yes |
| New disk
auto spare |
Yes |
Yes |
Yes |
| Environment
monitor |
Yes |
Yes |
Yes |
| Smart-function
LCD |
Yes |
Yes |
Yes |
| Bad block
auto-remapping |
Yes |
Yes |
Yes |
| UPS connection |
Yes |
Yes |
Yes |
| Power
requirements |
AC 90V ~ 254V Full
range
12 A/6A, 50 Hz/ 60 Hz
|
AC 90V ~ 254V Full
range
12 A/6A, 50 Hz/ 60 Hz |
AC 90V ~ 254V Full
range
12 A/6A, 50 Hz/ 60 Hz |
| |
|
|
|
| Relative
humidity |
10% to 85% Non-condensing |
10% to 85% Non-condensing |
10% to 85% Non-condensing |
| Operating
temperature |
10°C to 50°C (50°F to 122°F) |
10°C to 50°C (50°F to 122°F) |
10°C to 50°C (50°F to 122°F) |
| Non-operating
temperature |
-40°C
to 60°C (-40°F to 140°F) |
-40°C
to 60°C (-40°F to 140°F) |
-40°C
to 60°C (-40°F to 140°F) |
| |
|
|
|
| Aluminum
construction |
Yes |
Yes |
Yes |
| Dimensions |
5.24 (H) x 18.98 (W) x 23.98 (D) inches |
5.24 (H) x 18.98 (W) x 22.40 (D) inches |
5.24 (H) x 16.89 (W) 21.18 (D) inches |
| Weight |
45.1 lbs standard unit without drives |
40.7 lbs standard unit without drives |
55.0 lbs standard unit without drives |